JVP 4×4 panels are available in two thicknesses and four total densities, because not all floors need to provide the same level of performance. Every use has its own expected performance and needs, which must be taken into account to avoid design errors.
Using systems whose performance exceeds actual use does not represent a good safety standard, rather waste in terms of costs, consumption of raw materials, transport costs, installation and maintenance, and load on floors.

JVP 4×4 systems do not require additional cross-members, since they simply rest on the underlying structures. This is how we guarantee performance. There is also a corner-lock solution for each JVP 4× 4 panel allowing it to be screwed into the structure, further improving its performance, even for anti-seismic protection.


600×600 | 23 mm | bare panels without covering

logooooo

FSC-certified chipboard core


C3TTL000

gypsum fibreboard core


P3TTL000

download pdf download pdf
UNI EN 12825 *
Mechanical capacity

without cross-members
2/3,0/A/1 2/3,0/A/1
PSA MOB PF2 SPU
Mechanical
resistance
Light Grade Light Grade
UNI EN 13501-1
Reaction to fire
Bfl-s1 A2fl-s1
UNI EN 13501-2
Fire resistance
REI 30r REI 60r
UNI EN 140-12
UNI EN 717-1
Airborne sound
Dn,f,w 38 dB Dn,f,w 38 dB
UNI EN 140-12
UNI EN 717-2
Impact sound
Ln,f,w 71 dB Ln,f,w 70 dB
UNI EN 140-8
Interstorey noise
with acoustic pad
∆l,w 20 dB ∆l,w 21 dB
EN 15804
EPD standard
PCR 2012:01
EPD – IT17/0057 -SGS EPD – IT17/0056 -SGS
FSC recycled 100%
STD-40-004 V3 – 1
STD-50-001 V2 – 1
INT-COC -001121 non applicabile
VOC ISO 16000
Air comfort GOLD
Leed V4 BREEAM Int.
approvato/conforme approvato/conforme
Cradle to Cradle Certified™ BRONZE BRONZE

* EN12825 order and interpretation of standard data: breaking load/safety coefficient/maximum bending/dimensional tolerances.
The data contained in this publication have been substantiated by official third-party certificates.
The data contained in this publication are for information only, and are subject to change due to technical changes made to the products described.


600×600 | 29 mm | bare panels without covering

 

logooooo

FSC-certified chipboard core


C4TTL000

FSC-certified chipboard core


C5TTM000

FSC-certified chipboard core


C4TTM000

gypsum
fibreboard core


P4TTM000

gypsum
fibreboard core


P4TTH000

download pdf download pdf download pdf download pdf download pdf
UNI EN 12825 *
Mechanical capacity

without cross-members
3/3,0/A/1 4/3,0/A/1 5/3,0/A/1 5/3,0/A/1 6/3,0/A/1
PSA MOB PF2 SPU
Mechanical
resistance
Light Grade Euro Grade Medium Grade Medium Grade Heavy Grade
UNI EN 13501-1
Reaction to fire
Bfl-s1 Bfl-s1 Bfl-s1 A1fl A1fl
UNI EN 13501-2
Fire resistance
REI 60r REI 60r REI 60r REI 60r REI 60r
UNI EN 140-12
UNI EN 717-1
Airborne sound
Dn,f,w 42 dB Dn,f,w 46 dB Dn,f,w 46 dB Dn,f,w 50 dB Dn,f,w 50 dB
UNI EN 140-12
UNI EN 717-2
Impact sound
Ln,f,w 68 dB Ln,f,w 69 dB Ln,f,w 69 dB Ln,f,w 67 dB Ln,f,w 67 dB
UNI EN 140-8
Interstorey noise
with acoustic pad
∆l,w 21 dB ∆l,w 21 dB ∆l,w 21 dB ∆l,w 23 dB ∆l,w 23 dB
EN 15804
EPD standard
PCR 2012:01
EPD – IT17/0057 -SGS EPD – IT17/0057 -SGS EPD – IT17/0057 -SGS EPD – IT17/0056 -SGS EPD – IT17/0056 -SGS
FSC ricilcato 100%
STD-40-004 V3 – 1
STD-50-001 V2 – 1
INT-COC -001121 INT-COC -001121 INT-COC -001121 non
applicabile
non
applicabile
VOC ISO 16000
Air comfort GOLD
Leed V4
BREEAM Int.
approvato/
conforme
approvato/
conforme
approvato/
conforme
approvato/
conforme
approvato/
conforme
C2C Certified BRONZE BRONZE BRONZE BRONZE BRONZE

* EN12825 order and interpretation of standard data: breaking load/safety coefficient/maximum bending/dimensional tolerances.
The data contained in this publication have been substantiated by official third-party certificates.
The data contained in this publication are for information only, and are subject to change due to technical changes made to the products described.